Showing posts with label protection circuits. Show all posts
Showing posts with label protection circuits. Show all posts

0 Fuse Status Indicator Circuit


What this circuit do is provide status on the fuse installed thus it can help you in saving your time in troubleshooting especially when the problem is only the fuse (common problem). You can use this in your automobile or any DC devices powered by 12V battery. The circuit operation is summarized below.
1. Steady LED light - fuse is okay
2. Blinking LED (around 3 flashes per second) - fuse is broken
3. Off LED - no DC supply or the circuit is defective

schematic diagram
2N2222 pin
Part List:
Q1, Q2, Q3 - 2N2222 or similar NPN transistor
R1, R4 - 2.7 kilo ohms 1/4W
R2, R3 - 56 kilo ohms 1/4W
R5 - 1.2 kilo ohms 1/4W
R6 - 470 ohms 1/4W
C1, C2 - 4.7uF electrolytic capacitor rated 16V
D1, D2 - 1N4001 or any diode
LED - red or any low LED (see LED pinout in case you forget)

Other similar circuits:
Simple blown fuse indicator - Used in 220V AC circuits
Broken fuse indicator - DC fuse indicator circuit

3 Simple Low Voltage Protection Circuit


These circuits are very easy to construct and has very minimal parts. The circuit diagram below is a simple low voltage protection. The relay is a normally open (N.O.) and must be very sensitive type( operates even low current input). When the input voltage (Vin) is less than the forward voltage of the zener diode (VDz), no current will flow to the relay coil thus the load is isolated from the supply. 
simple low voltage protection
Circuit below is an improvised low voltage protection relay. When Vin is higher than VDz plus 0.7 (diode base emitter drop), the relay is close. On the other hand when Vin is lower, relay is open and load is isolated to the source. Main advantage compared to the circuit above is higher sensitivity in voltage change and requires only an ordinary type of relay.
modified version
The load is any device or equipment that works on DC. 

1 Simple blown fuse indicator

Have you tried wasting your time troubleshooting your equipment and to find out its just a blown fuse? Well this simple circuit indicator might help you not to experience that again. Two versions are  shown below.
simple blown fuse schematic
The two LEDs above will light up when fuse is broken. Circuit below is an improved fuse indicator, which at normal operation LED2 is on and LED1 is off. When the fuse is broken, LED1 is on and LED2 is off.
improved blown fuse indicator

Part List: (improved fuse indicator)
D - 1N4007 or similar diode
LED1- yellow or  any LED with higher forward voltage than LED1
LED2- red or any LED with much lower forward voltage than LED2
R-100 kilo-ohms


2 Broken Fuse Indicator using LED and transistor

Sometimes we found ourselves in great difficulty troubleshooting an
equipment. The funny thing is, upon spending so much time in front of
a defective circuit, the problem is only a broken fuse.

This simple project has a visual indicator in a form of LED
that help us know that the fuse is broken.
blown-fuse indicator schematic
This indicator circuit consists only 4 electronic components :
1. general purpose PNP transistor (ex. 9012,2N3906, others)
NPN transistor pins

2. LED or the light indicator
LED pins
3. general purpose silicon diode (1N4001, 1N4007, others)
    the cathode or negative is with white or gray band.
silicon Diode

4. 0.25W 100kilo-ohms resistor for transistor biasing.For resistor color
    you can use online resistor color code calculator.
100k resistor

Note: 
The broken fuse indicator circuit can only be used with an input voltage
ranges from 6V to 15V dc.